Boreal Geothermal Heat Pumps
Boreal ® Heat Pumps
features
Standard features
of Boreal ® Air Output heat pumps:
- Made In Canada
- Top or side discharge configuration
- Dual stages Copeland Scroll™ Compressor
- Safe non-ozone depleting R-410A refrigerant OR R-22 refrigerant (optional)
- Bi-directional filter rack
- Long life quiet self programmable direct drive ECM blower motor OR belt driven, variable speed PSC motor (optional)
- Desuperheater for domestic hot water production
- Quiet water valves
- Suction line accumulator
- Liquid line filter drier
- Sight Glass
- Thermostatic expansion valve
- Hard start kit
- Long life Turbotec® Expanded Surface coaxial heat exchanger
- Heat exchanger materials available : 316 Stainless Steel; Cupro-nickel; Cooper or Titanium
- Expanded Surface air heat exchanger
- Suitable for wastewater, open well or closed loop applications
- Voltage : 230/1/60; 230/3/60; 460/3/60; 575/3/60. European voltage (50hz) option
- Virtually maintenance free
- Made In Canada
- Maximum output water temperature 125°F
- High/Low service valves
- Refrigerant controlled head pressure valve
- Thermostatic Expansion Valve
- Easily accessible components
- Accumulator – Prevents liquid slugging during start-up
- Heavy duty Copeland® compressors in all models
- Desuperheater for domestic hot water production (optional)
- Heavy duty contactors
- Compact size (28”W * 32”L * 26”H) designed to produce large quantities of hot water
- Can be stacked up to 3 high in parallel configurations
- Highest efficiency Turbotec® Expanded Surface coaxial heat exchangers on each model
- Heat exchanger materials available : 316 Stainless Steel; Cupro-nickel; Cooper or Titanium
- Hi & Low pressure safety cutouts
- Internal circuit breaker protection for compressor and back-up electric heat
- Potential relay and start capacitor are standard on all 1 phase units
- Internal circuit breaker protection for compressor
- Expansion tank – pressure relief valve, pressure gauges
- Suitable for wastewater, open well or closed loop applications
- Voltage : 230/1/60; 230/3/60; 460/3/60; 575/3/60. European voltage (50hz) option
- Virtually maintenance free
- Made In Canada
- Top or side discharge configuration
- Dual stages Copeland Scroll™ Compressor
- Safe non-ozone depleting R-410A refrigerant OR R-22 refrigerant (optional)
- Long life quiet self programmable direct drive ECM blower motor OR belt driven, variable speed PSC motor (optional)
- Desuperheater for domestic hot water production
- Quiet water valves
- Liquid line filter dryer
- Long life Turbotec® Expanded Surface coaxial heat exchanger
- Heat exchanger materials available : 316 Stainless Steel; Cupro-nickel; Cooper or Titanium
- Accumulator- Prevents liquid sligging during start-up
- Bi-directional filter rack
- Hard start kits standard on all single phase models
- Maximum output water temperature 125°F
- High/Low service valves
- Refrigerant controlled head pressure valve
- Thermostatic Expansion Valve
- Easily accessible components
- Heavy duty contactors
- Internal circuit breaker protection for compressor and back-up electric heat
- Suitable for wastewater, open well or closed loop applications
- Voltage : 230/1/60; 230/3/60; 460/3/60; 575/3/60. European voltage (50hz) option
- Virtually maintenance free
- Made In Canada
- Heavy duty case constructed of 20 gauge 1mm satin galvanized panels with welded reinforcing channel stiffeners and corner posts.
- Finished inside and out with an oven baked epoxy enamel.
- Cabinet completely insulated with 1/2” to 1” acoustic insulation.
- Four removable access doors for easy servicing.
- Single Copeland Scroll compressor on 100 & 150 models, heavy duty Copeland “Tandem” compressor with sump heater on 300, 350, 400, 600 & 800 series.
- Oversized commercial duty compressor contactor rated for 2 million cycles.
- Integrated heavy duty electrical box enclosure with removable cover.
- Suction line accumulator & liquid line receiver.
- HW-100 utilizes Turbotec coaxial heat exchangers
- HW-150 to 800 incorporate high efficiency 316 SS brazed plate evaporator and condenser heat exchangers.
- Flow proving switches standard.
- Solid State Phase loss protector / anti short cycle timers.
- Filter drier and sight glass standard equipment.
- TXV refrigerant metering.
- Up to three “stage” capability with 40%, 50%, 60% and full output capacity on chosen models with “Tandem” compressors.
- Domestic hot water desuperheater coil and bronze head circulator pump for energy efficient production of domestic hot water.
- Operational and lock-out indicator lights.
- Optional dry contacts for remote alarms.
- Low water flow cutoff safety (flow switch).
- Low and high pressure / temperature refrigerant safety controls.
- Suitable for wastewater, open well or closed loop applications.
- Optional water valve for water well operation.
- All water lines constructed of copper with optional PVC piping available for harsh environments.
- CAN/CSA C22.2 NO 236-05 certified for electrical safety.
- CSA for performance as per CSA 446 M-94 (equivalent to ARI 325 & 330-98).
- Voltage : 230/3/60; 460/3/60; 575/3/60. European voltage (50hz) option.
- Virtually maintenance free.
- Uniweld construction with baked enamel finish. Acoustically insulated, satin galvanized and epoxy painted for corrosion protection
- Stainless Steel cabinet